Treatment Plant Overview

The wastewater treatment plant currently has a design daily flow of .680 MGD with a daily maximum flow of 1.525 MGD. In 2016 the average daily flow was .526 MGD, which is discharged into the Oconto River. The existing treatment facility uses trickling filters as its main treatment unit. As the water enters the plant it enters and flows thru a fine mechanically cleaned bar screen and compactor, grit removal, clarigester, trickling filters, and a final clarifier with solids contact unit. Before the water enters the Oconto River, it flows thru a seasonal (May 1-September 31st) disinfection system. The disinfection is achieved with the use of UV disinfection system. Phosphorus treatment is accomplished with the aid of ferric chloride addition in the final clarifier. Solids are treated in the anaerobic digestion unit of the clarigester. Excess solids produced within the digester are pumped into the sludge storage tank, where they are then spread onto DNR approved agricultural lands.

 

Laboratory and Pretreatment Program

The treatment plant is equipped with a laboratory to perform the majority of the process control analytical testing. Testing that is performed by the staff includes Biochemical Oxygen Demand (BOD), Total Suspended Solids (TSS), pH, Total Phosphorus, and Fecal Coliforms; which is required to meet our WPDES permit from the Wisconsin DNR.